  • 10-inch touchscreen
  • Control of Qbus Control and Qbus Building Control
  • Integrated video intercom and SIP functionality with QSD video door phone
  • Sleek and stylish design in black anodized aluminum
  • Flexible and simple installation

The QDISPLAY10 is a high-quality 10” touch display designed as the ideal central control for Qbus Control, Qbus Building Control, and QSD videophony. Its sleek black anodized aluminum design perfectly complements the modern Qbus range.

Thanks to its powerful hardware, guaranteed Android support, and full compatibility with existing Qbus installations, the QDISPLAY10 provides a fast, future-oriented, and user-friendly solution for both new construction and retrofit projects. With local functionality, offline control via Ubiebox, and SIP-call support, it combines design, performance, and reliability.

Technical info for installers

  • Function description

    The QDISPLAY10 is a high-quality 10" touch display designed as the ideal central control unit for Qbus Control, Qbus Building Control, and QSD videophony. With its sleek black anodized aluminum design, it perfectly complements the modern Qbus range.

    Thanks to its powerful hardware, guaranteed Android support, and complete compatibility with existing Qbus installations, the QDISPLAY10 offers a fast, future-oriented, and user-friendly solution for both new builds and retrofit projects. With local functionality, offline control via Ubiebox, and support for SIP calls, it combines design, performance, and reliability.

    The QDISPLAY10 fits into a standard single gang back box and supports PoE, PoE+, and 12–24V DC power supply.

    In addition to supporting QSD videophony, the QDISPLAY10 can also receive incoming doorbell calls via a classic doorbell and control a relay contact for door opening.

     

  • Technical specifications

    System

    • Android
    • Powerful embedded CPU
    • Direct start in Qbus Control / Qbus Building Control
    • OTA software updates
    • Software support: up to 10 years

    Display

    • 10” capacitive touchscreen
    • Resolution: 2K / 2000 × 1200
    • Operation: multi-touch
    • Finish: black anodized aluminum frame
    • Proximity and light sensor

    Network / Connectivity

    • Ethernet: RJ45 LAN or WiFi
    • Power supply: PoE / PoE+
    • Alternative power supply: 12–24V DC
    • Local network operation: fully supported
    • Offline functionality: via Ubiebox

    Audio & Videophony

    • Built-in microphone
    • Built-in speaker
    • SIP videophony with QSD
    • Two-way audio
    • Live video feed

    Inputs and Outputs

    • Bell-in classic doorbell input
    • Integrated potential-free relay contact, relay application: door opener / gate / lock control
    • QC output trigger on incoming call via QSD videophone

    Installation

    • Installation via standard single flush mount box
    • New construction and renovation

    Physical Dimensions

    • Width: 245mm
    • Height: 156mm
    • Thickness: 10mm

    Electrical Safety

    • FCC Class B, FCC Part 15
    • CE
    • RoHS / WEEE compliant
  • Sizing
    Q Display Dimensions
  • Explanation of symbols
    Symbool dubbele isolatie 229x50 fit 300dpi

    Equipment where protection against the risk of electric contact is not only based on basic insulation but also on additional protection such as double insulation or reinforced insulation. There is no possibility for grounding.

    Symbool gevaar aandachtig lezen 229x50 fit 300dpi

    Before connecting the device, it is mandatory to read the manual of the respective product. ISO7000-0434

    Symbool gevaarlijke spanning 229x50 fit 300dpi

    Power supply connection (230V) to the power supply connector. IEC 60417-5036

    Symbool CE keuring 229x50 fit 300dpi

    CE conformity. All declarations of conformity are available upon request.

  • Warranty provision

    Standard Warranty Period: 2 years from delivery date. The warranty is no longer valid if the module has been opened! Defective modules should be sent without seal along with a description of the defect to our service department:

    QBUS N.V. Joseph Cardijnstraat 19, 9420 Erpe-Mere, Belgium

    T +32 53 60 72 10 - F +32 53 60 72 19

    Email: [email protected]

General

  • Safety regulations

    Read the complete manual before installing and activating the display. If you do not follow the provided documentation, the product may be damaged and the manufacturer's warranty will be voided. Follow all installation guidelines that are provided with the product. Installing the product in high humidity environments, near heat sources and/or unapproved locations will impair, disrupt, and/or damage the intended operation of the product. Only use fittings and accessories specified by the manufacturer for use. Use of abrasive, liquid, or solvent-based cleaning fluids will damage the product. 

    ATTENTION

    • The display must be installed, started, and maintained by a qualified electrician in accordance with applicable national regulatory requirements.
    • The display is designed for installation in low humidity environments and should never be installed outdoors or in high humidity areas.
    • The display must not be opened. The warranty will be voided as soon as the display is opened!

Installation and wiring

  • Installation

    Installation Height

    The recommended installation height for the device is 110 cm - 160 cm from the finished floor to the bottom of the display.

    The display must be mounted in landscape orientation.

     

    Installation of the Single Flush-Mount Box

    Follow the supplied instructions from the flush-mount box manufacturer. 

    When using a fixed RJ45 connector, use an RJ45 connector without a boot. This is more compact and will offer greater flexibility. 

    Recommended flush-mount boxes: 

    • KAISER 9063-50 (depth 47mm)
    • HELIA 5021 (depth 48mm)

    Installing the Mounting Bracket

    The QDisplay10 is delivered with a mounting bracket and two ST3x20 screws which must be used for installation. 

    • Ensure that the arrow on the front of the flush module points upwards.
    • Set the torque of the electric screwdriver to 5 kgf·cm.
    • Attach the module with two ST3x20 screws to the flush mount box.
    • Ensure the module is mounted level and flush with the wall surface.
    Q Display Montagebeugel

    Mounting the QDisplay10

    Align the two clips on the built-in module with the cutouts in the panel, then snap the panel into place.

    Q Display Monteren
    • Ensure the panel is securely mounted and sits flush with the wall.
    • Locate the two screw holes at the bottom of the panel (each already has a screw).
    • Tighten both screws using the provided Allen key.
    Q Display Monteren2

    Starting the QDisplay10

    The device powers on automatically when activated. Wait for the device to boot up. When the device is connected to a network switch via an Ethernet cable, it receives a network address through DHCP and automatically connects.

    Removing the QDisplay10

    • Use the hex key to loosen the two screws at the bottom until the back of the panel is released.
    • Hold the top of the panel with one hand and pull the bottom forward to remove the panel.
    Q Display Verwijderen
  • Connection
    Q Display Aansluiten

    Connection options on the back of the display;

    • + terminal: Connect to the positive wire of a 12–24 VDC power supply if PoE or PoE+ is not used.
    • – terminal: Connect to the negative wire of a 12–24 VDC power supply if PoE or PoE+ is not used.
    • Bell-in: Dry contact input, optional. Can be connected to a traditional doorbell.
    • Relay output: 1-channel relay output, suitable for 0–30 VDC with a nominal current of 2 A. Optional.
    • RJ45 port: When connected to a PoE switch, both data and power are provided. When connected to a non-PoE switch, only the data connection is provided, and the display must be powered with the 12–24 VDC power supply.

    Connecting wiring;

    • Use wires with a conductor cross-section of 1.5 mm² to 2.5 mm² with stripped and straight ends.
    • Strip approximately 8 mm of insulation from each wire.

      Power supply

    • PoE: Connect an Ethernet cable from a PoE switch to the PoE port of the panel.
    • 12–24 V: Connect the positive and negative wires of the power adapter to the +- and -- terminals.

      Wired network connection

    • Insert the RJ45 network cable into the Ethernet port.

      Connection of a traditional doorbell (optional)

    • Connect the doorbell wires to the IO and Power_GND terminals.

      Connection of the relay output (optional)

    • Connect the negative wire to COM. If an external power supply is needed, connect accordingly.
    • Connect the positive wire to NO or NC, depending on the desired default contact position.

      Note: When connecting an electric strike, it is strongly recommended to add a rectifier diode (flyback diode) to protect the circuit.