Skip to main content
SEN01 MB 306x0
SEN01 MW 306x0
SEN01MB

Mini motion and light sensor

Execution: Black
  • Detects motion and light levels
  • Compact and discreet flush-mount design with white or black sensor
  • Wide detection range: up to 7 meters with a 110° angle
  • Fully configurable via System Manager III
  • Can be finished with central plates

The design detector SEN01M is a small motion detector that can be integrated into skirting boards, cabinets, walls, etc. The SEN01M also has a built-in light sensor and a range of 7 meters at an angle of 110°. Available in white (SEN01MW) and black (SEN01MB)

Frequently Asked Questions

  • How do you read an existing configuration?

    This is a completely different procedure depending on the type of controller.

    • For the CTD controllers this goes as follows:

    In the SMIII via "File" or "Utilities / Setup / SD card", click on "Recover QDB from SD".

    After confirmation you choose the name and location where the file should be saved. The zipped QDB file is then read from the SD card of the CTD and saved. With a positive answer to the question "Unzip and open restored QDB?", All data will then be immediately available. If the data you were still working on was not sent or saved, you will first receive a notification to do so.

     

    • For a CTL controller follow the following procedure:

    Because this controller does not yet have a large memory, only limited data can be recovered. Ao the names are abbreviated to 12 characters and serial numbers are not stored anywhere.

    The first step is therefore to type in ALL serial numbers via SMII via "File / Modules". These 6-digit serial numbers can be found on every module (DIN rail, switch, detector, etc.). For the SWC0x switches, an extra option was provided to have them send their serial number via “Search for modules”.

    When you then click on the "down arrow", you can read all this limited information.

  • Always use the latest software for configuration.

    It is always recommended to use the most recent version. This version supports the newest modules and resolves all known bugs.

    If, for example, you enter a serial number and the correct module information does not appear, you are likely not working with the most recent software.

    A newer version will always be able to open the older files (.QDB) without data loss.

    The latest version of the System Manager software, along with the user manual and version history, can be found in the knowledge center.

Technical info for installers

  • Function description

    This module contains a motion sensor and beneath it a light cell. The motion sensor has a diameter of only 9mm. The range is approximately 7 meters at an angle of 110 degrees. 

    Through the Qbus Configuration Software (System Manager), it can be set that the respective output is only activated when a certain light level or a certain volume of movement or a combination of both is reached.

    The SEN01M is available with a white motion sensor (SEN01MW) and with a black motion sensor (SEN01MB) 

       

  • Technical specifications

    GENERAL SPECIFICATIONS:

    • Power supply: bus connection
    • Ambient temperature: 

    Operational temperature: 10°C to 60°C

            Storage temperature: -10°C to 85°C

    • Maximum humidity level: 93%, no condensation
    • Bus load: 8mA at nominal voltage 13.8V.
    • Maximum installation height: 2,000 meters.

    PHYSICAL SPECIFICATIONS

    • Casing: Plastic, encapsulated in resin
    • Protection rating: IP20, EN 60529
    • Installation: direct on the bus
    • Dimensions (HxW): 30mm x 23mm
    • Weight: approximately 10 grams

    ELECTRICAL PROTECTION

    • Bus: 13.8VDC low voltage
    • In accordance with EN 60950 – 1:2006

    CE

    • In accordance with EMC and low voltage regulations. The module complies with HBES – EN50090-2-2 and EN60950 – 1: 2006.

     

    DETECTION ZONE

    Detectiehoek
  • Sizing
    Losse sen afmetingen
    Detectiehoek
  • Explanation of symbols
    Symbool Dubbele isollatie

    Equipment where protection against the risk of electric contact is not only based on basic insulation but also on additional protection such as double insulation or reinforced insulation. There is no possibility for grounding.

     

    Symbool Gevaar Aandachtig lezen

    Before connecting the device, it is mandatory to read the manual of the respective product. ISO7000-0434

    Symbool Gevaarlijke spanning

    Power supply connection (230V) to the power supply connector. IEC 60417-5036

    Symbool CE

    CE conformity. All declarations of conformity are available upon request.

  • Warranty provision

    Standard Warranty Period: 2 years from delivery date.

    The warranty is no longer valid if the module has been opened! 

    Defective modules should be sent without seal along with a description of the defect to our service department:

    QBUS N.V.

    Joseph Cardijnstraat 19

    9420 Erpe-Mere

    Belgium

    T +32 53 60 72 10

    F +32 53 60 72 19

    Email: support@qbus.be

     

General

  • Safety regulations

    Read the full manual before installing the module and activating the system. 

     WARNING

    • The module must be installed, started, and maintained by a certified electrical installer in accordance with the applicable legal regulations of the country.
    • The module can be used for permanent installation in dry indoor locations.
    • The module must not be opened. The warranty will be void if the module is opened!

Installation and wiring

  • Installation

    Connect the bus cable to the back of the SEN01. 

    IMPORTANT: THE BUS MUST NEVER COME INTO CONTACT WITH THE GROUNDING OR A LIVE CONDUCTOR!

    For the installer or end user who prefers a fully finished sensor module, there is the motion and light sensor in a round recessed fixture for both hollow and solid walls.

  • Power Supply

    The SEN01M is powered via the bus

    IMPORTANT: THE BUS MUST NEVER COME INTO CONTACT WITH THE GROUNDING OR A LIVE CONDUCTOR!

  • BUS connection

    It is recommended to use the Qbus cable or any other cable with a minimum of 2 conductors of 1mm² as the bus cable. The green shielded EIB cable can also be used if the conductors are paired to achieve a minimum cross-section of 2 x 1mm².

Each modules has an unique serial number. By this number the System Manager recognizes the modules.

This is completely explained in our knowledge center.

 

After entering the serial number or selecting the module, following screen appears:

Qbus System Manager III Manual Update 04 2025 pdf image 420

The SEN01 can switch a bistable I/O according to the set values.

Extension: is the time the I/O will remain on when no more motion is detected.

First: The magnitude of the movement necessary to activate the I/O. A larger value will therefore trigger the I/O a little later.

Keep: The amount of movement necessary to keep the I/O active. Values greater than or equal to the "First" option are excluded.

Light level: If 'Only if “Dark”' is checked, the I/O will be activated if the measured light value is lower than the set threshold value.
The current light value will be displayed with a yellow bar via the “Read values” button. When the threshold value is in the colored bar, the I/O will be activated upon movement.

The SCAN-button shows the level of motion. See also SEN04MLT