Skip to main content
Ubietouch Zwart
Ubietouch Wit
UbieTouch8BL

UbieTouch 8" touchscreen display

Execution: Black
  • 8-inch touchscreen
  • Control via Qbus Control
  • Built-in videophone functionality
  • Stylish design available in 2 colours
  • Optional aluminium holder available

This 8-inch capacitive color touchscreen allows intuitive operation of a Qbus installation. It features a built-in speaker and smart microphone for optimal audio recording and can also serve as an indoor unit for a video intercom system (linked with a SIP outdoor unit). The screen is POE powered and requires a wired network. The UbieTouch can also be placed on an optional metal holder.

Control

In our knowledge center, you can read how to operate your UbieTouch: Qbus Control operations

Technical info for installers

  • Function description

    The UbieTouch display is an 8-inch touchscreen used to visualize and control your Qbus or Ubie installation. The screen can also function as the indoor panel of the videophone system (compatible with videophone outdoor units using the SIP protocol).

    The UbieTouch display has an RJ45 connection for connecting to an Ethernet cable. 

    The display is available in white or black finish.

    Included in the box:

    • 1 x UbieTouch screen

    • 1 x mounting bracket compatible with a Bticino 506E wall mounting box

    • 4 x mounting screws

  • Technical specifications

    System Architecture

    • iMX8 Dual Core processor
    • 1.8GHz
    • 64-bit H.265 1080p Full-HD video playback
    • 3D graphics

    Memory

    • 2GB LPDDR4
    • 8GB eMMc

    Display

    • High-performance HD, ISP 8” LCD, 1280x800 resolution
    • Color depth: 16.7M colors, 400 nits brightness
    • Five-finger capacitive touchscreen with multi-touch support
    • Proximity and light sensor

    Audio

    • High-fidelity audio with 2W amplifier
    • Smart microphone for high quality voice recording
    • VoIP SIP client

    Network / Connectivity

    • Gigabit Ethernet controller

    Software

    • OS: Android 6.01
    • The Ubie application.

    Power Supply

    • Isolated PoE 13W
    • 24DC 

    Physical Specifications

    • Dimensions (H x W x D): 148.4mm x 223.5mm x 15.8mm 

    Electrical Safety

    • FCC Class B, FCC Part 15
    • CE
    • RoHS / WEEE compliant
  • Sizing
  • Explanation of symbols
    Symbool Dubbele isollatie

    Equipment where protection against the risk of electric contact is not only based on basic insulation but also on additional protection such as double insulation or reinforced insulation. There is no possibility for grounding.

     

    Symbool Gevaar Aandachtig lezen

    Before connecting the device, it is mandatory to read the manual of the respective product. ISO7000-0434

    Symbool Gevaarlijke spanning

    Power supply connection (230V) to the power supply connector. IEC 60417-5036

    Symbool CE

    CE conformity. All declarations of conformity are available upon request.

  • Warranty provision

    Standard Warranty Period: 2 years from delivery date.

    The warranty is no longer valid if the module has been opened! 

    Defective modules should be sent without seal along with a description of the defect to our service department:

    QBUS N.V.

    Joseph Cardijnstraat 19

    9420 Erpe-Mere

    Belgium

    T +32 53 60 72 10

    F +32 53 60 72 19

    Email: support@qbus.be

     

General

  • Safety regulations

    Read the full manual before installing the module and activating the system. Failure to follow the provided documentation may damage the product and void the manufacturer's warranty. Follow all installation guidelines provided with the product. Installing the product in high humidity environments, near heat sources, and/or in non-recommended locations will impair, disrupt, and/or damage the intended operation of the product. Only use attachments and accessories specified for use by the manufacturer. The use of abrasive, liquid, or solvent-containing cleaning agents will damage the product. Product maintenance must ONLY be carried out by authorized or certified service centers and personnel. Refer to the product documentation for a complete list of product maintenance options and/or contact the original manufacturer for further information.

    ATTENTION

    • The module must be installed, started, and maintained by a qualified electrician in accordance with applicable national legal regulations.
    • The device is designed for installation in low humidity environments and must never be installed outdoors or in high humidity areas.
    • The module must not be opened. The warranty is void once the module is opened!

Installation and wiring

  • Installation

    Installation Height

    The recommended mounting height for the device is 145 cm -165 cm from the finished floor to the center of the unit.

    The device can be mounted and oriented in portrait or landscape.

     

    Installation of the Bticino 506E Wall Mount Box

    ATTENTION: The Bticino 506E wall mount box must be mounted with the fixing holes at the top and bottom (rotated 90°). 

    PB526 N

    Installing the Mounting Bracket

    The UbieTouch comes with a stainless steel mounting bracket that must be used for installation. The screw holes of the mounting bracket align with the screw holes of a Bticino 506E wall mounting box. Ensure the bracket is level before tightening the secured screws onto the device.

    Ubie Touch White Left

    Mounting the UbieTouch

    1. First, loosen the secured screws on the device. Screws should not be moved away from the device. Comply with the indicated line.

    2. Align the hooks of the mounting frame with the mounting slots and gently pull the device down from the mounting bracket. Ensure that the mounting hooks are securely fastened.

    3. To complete the installation, tighten the 2 secured screws at the bottom of the device to attach the device to the mounting bracket.

    4. For portrait orientation, rotate the mounting bracket 90 degrees counterclockwise for installation.

    Starting the UbieTouch

    The device starts automatically when it is powered on. Wait for the device to boot up. When the device is connected to a network switch via an Ethernet cable, it receives a network address via DHCP and automatically connects to the system.

    Removing the UbieTouch

    Loosen the 2 secured screws on the device and then pull slightly straight up from the mounting frame to disconnect the device.

  • Power supply

    Connecting the device to power

    The device is designed to be powered via the Ethernet connection (PoE) or by connecting a 24V DC power supply (not included), but not both. If both the PoE and a 24V DC power supply are connected, the device will draw power from the 24V DC source.

    PoE connection

    PoE connection requires the IEEE 802.3af standard. Use a network switch or PoE injector that meets this standard. Connect the device using a standard T568A or T568B Ethernet cable from the network switch to the LAN / Po port on the back of the device.
    24V DC power supply

    You can provide power to the device locally or remotely by using a 24V DC power supply (not included). Please note that the wire runs through the wall in accordance with local codes when using local power supply. If powering remotely, ensure to use a wire suitable for the length of the run. Use an approved 24V DC power supply.

    Check the polarity of the round connector on your power supply before connecting it to the device. The center pin of the device’s power connector is positive, and the outer ring is negative. If the wire is extended, ensure the routing complies with local codes. Insert the connector into the DC port on the back of the device.