Skip to main content

Qbox2

Qbox2 3

Home Automation Module for the Project Market

The Qbox2 is an all-in-one home automation module for the project market. The module is developed for property developers and installers who require an affordable, easy-to-install, and future-proof electrical installation for each residential unit. The system is installed in a single residential unit and can automate all controls (lighting, screens, power outlets) there.

14 relay outputs and 14 potential-free inputs
Flexible control of lighting, blinds and power outlets.
2 DALI channels for up to 64 DALI drivers
Integrated DALI control for smart lighting management.
5 configurable scene inputs
Combine multiple actions at the touch of a button.
Built-in Wi-Fi Access Point
Easily configure the module without additional network equipment.
Plug-in connectors for quick installation
Efficient connections and easy installation in the electrical distribution board.

Specifications

  • Funtion description

    The Qbox2 is an all-in-one domotics module for the project market. The module is developed for property developers and installers who want to provide an affordable, easy-to-install, and future-oriented electrical installation per residential unit.

    The system is installed in one residential unit and can automate all controls there (lighting, screens, sockets). 

    The unit is part of the Qbus Stand-Alone range and can operate by itself – so WITHOUT a Qbus Controller – but can also be connected to a Qbus controller to become part of a complete Qbus installation that, for example, controls all rooms on a floor.

    The Qbox2 must always be powered by an external 230VAC power supply.

    The Qbox2 module is configured via System Manager III and can be connected to the PC running the program via...

    • ethernet connection
    • or via WiFi access point (press SEL + MAN buttons for 2 seconds to activate or deactivate the access point)
    • or via the bus connected to a controller.

    On the 14 relay outputs, different timer functions can be activated: timer 1 (where one pulse activates the output for a predetermined duration), timer 2 (where one pulse activates the output and a second pulse while the timer is running extends the timer for the same duration) or timer 3 (where one pulse activates the output and a second pulse while the timer is running activates the output until a third pulse deactivates the output). 

    The settings of the outputs are visually separated in SMIII from “extra settings”. Under extra settings are the general settings relating to the entire module.

    Read mode and status can be viewed via SMIII, both in Standalone and on the bus.

    SMIII contains a photo of the Qbox2. Clicking the photo provides a page with product information.

    The inputs can be set as Normally Open, Normally Closed, or as a pushbutton.

    For controlling shutters, curtains, or sunblinds (anything with a motor), the Qbox2 outputs can be programmed in motor mode. In motor control, the outputs for up and down are automatically linked: for example, if output one is assigned the function “motor”, output 2 is automatically linked to it.

    The relay outputs are operated one-to-one by 14 potential-free inputs. The module also contains 4 LED outputs for feedback on switches. An external 5-24VDC power supply must be installed for this.

    The relay outputs can be manually operated on the Qbox2 module using the SEL + ON/OFF buttons. You remain in manual operation for 10 seconds after the last operation.

    • Press SEL once.
      • Relay 1 long off, short on = output off; relay 1 long on, short off = output on. Press ON/OFF to change the status.
    • Press SEL to move to the next IO.

    The Qbox2 is also suitable for controlling 64 DALI drivers. The DALI dimmer parameters of the drivers are stored in memory. When replacing or adding drivers, the Qbox2 only needs to be restarted to position the parameters correctly. These are dispatched by the Qbox2 upon restart for smooth and correct driver replacement.

    In case heavy loads or two-pole applications are connected, contactors must be added. A relay contact of the Qbox2 will then activate the coil of the contactor.

    The Qbox2 module has 2 potential-free inputs (D1 & D2) for controlling the Dali channels via standard pushbuttons. Input 1 controls channel 1, input 2 controls channel 2. 

    The Qbox2 module has 5 scene inputs (P1…P5) that can be configured separately to perform a combination of actions such as closing the roller blinds and turning on and dimming the lights when the “evening” scene is selected.

    Via the Ethernet connection, the module can be connected to the network to perform configuration via the network, or to link the Qbox2 module to other IP-controlled systems such as Ubie Pro servers for linking with emergency call systems. Ethernet connection is also essential for upgrading the module. The upgrade firmware is offered OTA (over the air), but the upgrade must always be initiated via SMIII.

    If the module is restarted after a power failure, the outputs will return to their last position.

    The module is equipped with plug connectors for quick installation. 

    For bus-controlled Qbox2, the configured Qbox2 functionalities will still operate if bus communication fails (fail ctd).

  • Technical specifications

    General Specifications:

    • Power supply: 230VAC
    • Dielectric strength: tested at 3 kVAC
    • Consumption: 7.2VA, with all relay outputs on
    • Operating temperature: 10°C to 70°C
    • Storage temperature: -10°C to 70°C
    • Maximum humidity level: 93%, non-condensing
    • Bus load: 10mA (peak) at nominal voltage 13.8V
    • Maximum installation height: 2,000 meters above sea level

    Technical Features

    •  14 relay outputs each max 10A on the top for connecting lighting, shutters, or sockets (230VAC and low voltage) – 1…14
    • 230VAC can be combined with low voltage if a different common is used.
      • common 1: outputs 1…4
      • common 2: outputs 5…8
      • common 3: outputs 9…12
      • common 4: output 13
      • common 5: output 14
    • LED indication per output
    • 2 DALI broadcast channels (DALI BC) at the bottom to control up to 64 DALI drivers.
    • 14 potential-free inputs at the bottom, 1 to 1 linked to relay outputs 1…14 – Input 1…14, of which 4 with LED feedback (1...4, bottom)
    • 2 dimmer inputs at the bottom for DALI control
    • 5 potential-free mood inputs at the bottom – P1…P5
    • 1 "A" input at the bottom (all off/panic)
    • 1 network connection at the bottom, set to dhcp (ETH)
    • 1 230VAC power connection – 230VAC, top
    • 1 Qbus bus connection at the bottom – BUS
    • Integrated WiFi access point mode with status LED access point for quick configuration

    Maximum Current and Power Load

    Maximum Current: 

    • Resistive load (cosj = 1): 10A at 230VAC / 30VDC
    • Inductive load (cosj = 0.4; L/R = 7 ms): 5A at 230VAC / 30VDC

    Maximum Switching Power: 

    • Resistive load (cosj = 1): 2300VA at 230VAC; 300W at 30VDC
    • Inductive load (cosj = 0.4; L/R = 7 ms): 1150VA at 230VAC; 150W at 30VDC

    If higher currents need to be switched, an external contactor must be used.

    Physical Specifications

    • Housing: plastic, self-extinguishing according to UL94-V0
    • Protection degree: IP20, EN 60529
    • Installation: quick mounting on DIN-rail, width 12 modules
    • Dimensions (h x w x l): 62mm x 90mm x 212mm CHECK!!
    • Weight: approximately 0.430 kg CHECK!!

    Electrical Safety

    • Bus: 13.8VDC low voltage
    • Compliant with EN60950 – 1: 2006
    • Non-toxic, compliant with WEEE/RoHS
    • Compliant with EMC and low voltage regulations. The module complies with HBES – EN50090-2-2 and EN60950 – 1: 2006 +A11:2009 + A1:2010 + A12:2011 + A2:2013
  • Dimensions
    Qbus module met maataanduidingen
  • Explanation of symbols
    Symbool dubbele isolatie 229x50 fit 300dpi

    Equipment where protection against the risk of electric contact is not only based on basic insulation but also on additional protection such as double insulation or reinforced insulation. There is no possibility for grounding.

    Symbool gevaar aandachtig lezen 229x50 fit 300dpi

    Before connecting the device, it is mandatory to read the manual of the respective product. ISO7000-0434

    Symbool gevaarlijke spanning 229x50 fit 300dpi

    Power supply connection (230V) to the power supply connector. IEC 60417-5036

    Symbool CE keuring 229x50 fit 300dpi

    CE conformity. All declarations of conformity are available upon request.

  • Warranty

    2 years from the date of delivery. The warranty becomes void if the module has been opened! The warranty period is extended by 2 years if it was installed by a certified Qbus installer.

    In case of defects, Qbus support should be contacted by a certified installer. After registration with Qbus support, the defective module can be sent, unsealed and with a description of the defect, to our Qbus support.

    QBUS N.V. Joseph Cardijnstraat 19, 9420 Erpe-Mere, Belgium

    T +32 53 60 72 10 - F +32 53 60 72 19

    Email: [email protected]

Installation

  • Safety regulations

    Read the entire manual before installing the module and activating the system.

    Warning

    • The module must be installed, initialized, and maintained by a certified electrical installer in accordance with the applicable legal regulations of the country.
    • This module is only suitable for DIN rail installation EN50022. The module must be installed in a fire-proof, enclosed distribution box with ventilation grids.
    • Before working on the Qbox2, the power supply must be turned off.
    • Never connect alternating current (e.g., 230VAC) to the Qbus bus or inputs! This will cause irreversible damage to the module and/or connected devices.
    • The module must not be opened. The warranty is void if the module is opened!
    • Never use the power supply of the Qbus Controller to power the LED indicators on stand-alone modules!
  • Installation

    Click the module onto a DIN rail DIN EN50022.

  • Power Supply

    The module is powered by a 230VAC power supply.

  • Connectors

    The Qbox2 is equipped with plug connectors for quick and efficient wiring.

  • Inputs

    Remove approximately 7mm of insulation from the cable and insert the cable into the terminals. Both solid and stranded cables between 0.5 – 1.5 mm2 can be used.

  • LED feedback

    An external 5-24VDC power supply can be connected to the Qbox2 to provide LED feedback on the various push buttons via the LED outputs.

  • Load

    Connect the loads to the output connectors. The cross-section of the conductor at maximum load is a minimum of 1.5mm². Remove approximately 7mm of insulation from the conductor and screw the conductor into the designated connectors. If relay sockets are connected, a separate contactor must be connected (a 2P/20A contactor is required).

  • Cabling methods

    Option 1: stand-alone

    • Multiple stand-alone modules can be linked together.

    Option 2: with Qbus controller

  • BUS connection

    Use the green shielded EIB cable as the recommended cable when the conductors are twisted together in pairs to achieve a section of at least 2 x 1 mm². You may use a cable of equivalent quality. The shielding of the bus cable must, and may only, be connected at one end to the general grounding of the building.

Configuration

  • Configuration via System Manager III

    Using System Manager III, you can configure each module via the bus. This is clarified through our knowledge center.

    When you have entered the serial number of a Qbox2 in the module window, the following screen appears.