All heat pumps with a Smart Grid contact (2 contacts provided on 90% of all new heat pumps) can be controlled with Luqas. We tested the following:
Brand | Type | Connection relay 1 | Connexion relay 2 |
Alpha Innotec | SW H3 • SWC(V) H1/H3 • WZS(V) H3 • PWZS(V) H1/H2/H3 | IN5 | IN6 |
LWCV • LWDV • LW(A)V • LW(A)HV • LWAV+ • Paros • LWP | IN3 | IN4 | |
Daikin | Altherma 2 CB series(1) | LAN adapter: X1A/1+2 | LAN adapter: X1A/3+4 |
Altherma 3 D-series (1) | LAN adapter: X1A/1+2 | LAN adapter: X1A/3+4 | |
Altherma 3 E-series | X5M/9+10 | X5M/5+6 | |
Mitsubishi | Ecodan C-series generatie R2 | TBI.3 IN11 | TBI.3 IN12 |
Ecodan D-series | TBI.3 IN11 | TBI.3 IN12 | |
Ecodan E-series | TBI.3 IN11 | TBI.3 IN12 | |
Nibe | All heat pumps | Connecting and assigning to AUX contact | Connecting and assigning to AUX contact |
Thermastage | Thermastage Compact 05-11 | EX1 | EX2 |
Thermastage Compact 13-16 | EX1 | EX2 | |
Thermia | Atlas | BM card: D21 (408) or EM3 card D95 (408) | BM card D22 (409) or EM3 card D96 (409) |
Calibra | BM card: D21 (408) or EM3 card D95 (408) | BM card D22 (409) or EM3 card D96 (409) | |
Mega | BM card: D21 (408) or EM3 card D95 (408) | BM card D22 (409) or EM3 card D96 (409) | |
Athena | BM card: D21 (408) or EM3 card D95 (408) | BM card D22 (409) or EM3 card D96 (409) | |
Vaillant | aroTHERM pure /7.2 (uniTOWER /7.2) | S21 | X41/FB + 0(ꓕ) |
aroTHERM plus /6 (uniTOWER VIH /6 / VWZ MEH 97) | S21 | X41/FB + 0(ꓕ) | |
aroTHERM /5 | S21 | X41/FB + 0(ꓕ) | |
flexoCOMPACT /4 | S21 | X41/FB + 0(ꓕ) | |
flexoTHERM /4 | S21 | X41/FB + 0(ꓕ) | |
aroTHERM VWL /2 | S21 | X41/FB + 0(ꓕ) | |
Viessmann | All Vitocal heat pumps (since 08/2018). | W01C control: 216.1 | W01C control: 216.4 |
LAN adapter module required (version BRP069A61)
This list is not exhaustive. Other Smart Grid-ready heat pumps can be found at https://www.waermepumpe.de/normen-technik/sg-ready-datenbank/.
Please contact an advisor.